High selectivity with double-layer detector and optical coupler
Reliable measurements even in complex gas mixtures
Low detection limits
Measurements with low concentrations
Corrosion-resistant materials in gas path (option)
Measurement possible in highly corrosive sample gases
Analyzer cells can be cleaned as required on site
Cost savings due to reuse after contamination
Electronics and physics: gas-tight isolation, purging is possible, IP65
Long service life even in harsh environments
Heated versions (option)
Use also in presence of gases condensing at low temperature
EEx(p) for zones 1 and 2 (according to ATEX 2G and ATEX 3G)
Application
Fields of application
Measurement for boiler control in incineration plants
Emission measurements in incineration plants
Measurement in the automotive industry (test benches)
Warning equipment
Process gas concentrations in chemical plants
Trace measurements in pure gas processes
Environmental protection
TLV (Threshold Limit Value) monitoring at the workplace
Quality monitoring
Ex versions for analyzing flammable and non-flammable gases or vapors for use in hazardous areas
Special versions
Special applications
Besides the standard combinations, special applications concerning material in the gas path, material in the sample chambers (e.g. Titan, Hastelloy C22) and measured components are also available on request
TÜV version/QAL
TÜV-approved versions are available for measurement of CO, NO and SO2 according to 13th and 17th BlmSchV and TA Luft.
Smallest TÜV-approved and permitted measuring ranges:
1-component analyzer
CO: 0 to 50 mg/m3
NO: 0 to 100 mg/m3
SO2: 0 to 75 mg/m3
2-component analyzer (series connection)
CO: 0 to 75 mg/m3
NO: 0 to 200 mg/m3.
Furthermore, the TÜV-approved versions of the ULTRAMAT 6 comply with the requirements of EN 14956 and QAL 1 in accordance with EN 14181. Conformity of the analyzers with both standards is TÜV-certified.
The analyzer drift can be determined in accordance with EN 14181 (QAL 3) either manually or with a PC using the SIPROM GA maintenance and servicing software. In addition, selected manufacturers of emission evaluation computers offer the possibility for downloading the drift data via the analyzer’s serial interface and to automatically record and process it in the evaluation computer.
Flow-type reference compartment
The flow through the reference compartment should be adapted to the sample gas flow
The gas supply of the reduced flow-type reference compartment should have an upstream pressure of 3 000 to 5 000 hPa (abs.). Then a restrictor will automatically adjust the flow to approximately 8 ml/min
High selectivity with double-layer detector and optical coupler
Reliable measurements even in complex gas mixtures
Low detection limits
Measurements with low concentrations
Corrosion-resistant materials in gas path (option)
Measurement possible in highly corrosive sample gases
Analyzer cells can be cleaned as required on site
Cost savings due to reuse after contamination
Electronics and physics: gas-tight isolation, purging is possible, IP65
Long service life even in harsh environments
Heated versions (option)
Use also in presence of gases condensing at low temperature
EEx(p) for zones 1 and 2 (according to ATEX 2G and ATEX 3G)
Application
Fields of application
Measurement for boiler control in incineration plants
Emission measurements in incineration plants
Measurement in the automotive industry (test benches)
Warning equipment
Process gas concentrations in chemical plants
Trace measurements in pure gas processes
Environmental protection
TLV (Threshold Limit Value) monitoring at the workplace
Quality monitoring
Ex versions for analyzing flammable and non-flammable gases or vapors for use in hazardous areas
Special versions
Special applications
Besides the standard combinations, special applications concerning material in the gas path, material in the sample chambers (e.g. Titan, Hastelloy C22) and measured components are also available on request
TÜV version/QAL
TÜV-approved versions are available for measurement of CO, NO and SO2 according to 13th and 17th BlmSchV and TA Luft.
Smallest TÜV-approved and permitted measuring ranges:
1-component analyzer
CO: 0 to 50 mg/m3
NO: 0 to 100 mg/m3
SO2: 0 to 75 mg/m3
2-component analyzer (series connection)
CO: 0 to 75 mg/m3
NO: 0 to 200 mg/m3.
Furthermore, the TÜV-approved versions of the ULTRAMAT 6 comply with the requirements of EN 14956 and QAL 1 in accordance with EN 14181. Conformity of the analyzers with both standards is TÜV-certified.
The analyzer drift can be determined in accordance with EN 14181 (QAL 3) either manually or with a PC using the SIPROM GA maintenance and servicing software. In addition, selected manufacturers of emission evaluation computers offer the possibility for downloading the drift data via the analyzer’s serial interface and to automatically record and process it in the evaluation computer.
Flow-type reference compartment
The flow through the reference compartment should be adapted to the sample gas flow
The gas supply of the reduced flow-type reference compartment should have an upstream pressure of 3 000 to 5 000 hPa (abs.). Then a restrictor will automatically adjust the flow to approximately 8 ml/min