SPECIFICATIONS
Excitation: 10 to 36 Vdc unregulated
Output: PX603/PX613 Series: 1 to 5 Vdc (3 wire)
PX605/PX615 Series: 4 to 20 mA (2 wire)
Supply Current: <3.0 mA
Insulation Resistance: 100 MΩ @ 50 V
Accuracy: ± 0.4% BFSL (Includes non-linearity, hysteresis and non-repeatability errors)
± 1.0% Terminal Point Method Includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors
Hysteresis: ± 0.2% FS
Repeatability: ± 0.07% FS
Stability: ± 1.0%/year
Durability: 100 million cycles
Operating Temperature: -28 to 82°C (-20 to 180°F)
Compensated Temperature: -28 to 71°C (-20 to 160°F)
Thermal Zero Effect: ± 0.04% FS/°F
Thermal Span Effect: ± 0.04% FS/°F
Proof Pressure:
15 to 2000 psi = 200% FS
3000 to 5000 psi = 150% FS
7500 to 20,000 psi = 120% FS
Burst Pressure:
15 to 2000 psi = 800% FS
3000 to 5000 psi = 300% FS
7500 to 20,000 psi = 150% FS
Gages: Thin-film polysilicone
Diaphragm: 17-4 PH stainless steel
Case: 300 Series stainless steel
Pressure Connection:
15 to 10,000 psi = 1/4; NPT
>10,000 psi = female Aminco fitting (9/16-18 UNF)
Electrical Connection: 0.9 m (36′) braided-shield PVC cable or connector
Mating Connector: PT06F8-4S (not included)
Weight: 128 g (4.5 oz) without cable
Response Time: 5 ms
Construction: Sealed units, except PX603 and PX605 ≤500 psi is vented to room
- Excellent Long Term Stability
- All Stainless Steel Construction
- NEMA 4 Cable or Connector Models
- 0.4% Accuracy
The new way to pay from Process Instrument Solutions.
Dwyer Omega – PX603-PX613-PX605-PX615 General Purpose Pressure Transducers with Adjustable Zero & Span
SPECIFICATIONS
Excitation: 10 to 36 Vdc unregulated
Output: PX603/PX613 Series: 1 to 5 Vdc (3 wire)
PX605/PX615 Series: 4 to 20 mA (2 wire)
Supply Current: <3.0 mA
Insulation Resistance: 100 MΩ @ 50 V
Accuracy: ± 0.4% BFSL (Includes non-linearity, hysteresis and non-repeatability errors)
± 1.0% Terminal Point Method Includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors
Hysteresis: ± 0.2% FS
Repeatability: ± 0.07% FS
Stability: ± 1.0%/year
Durability: 100 million cycles
Operating Temperature: -28 to 82°C (-20 to 180°F)
Compensated Temperature: -28 to 71°C (-20 to 160°F)
Thermal Zero Effect: ± 0.04% FS/°F
Thermal Span Effect: ± 0.04% FS/°F
Proof Pressure:
15 to 2000 psi = 200% FS
3000 to 5000 psi = 150% FS
7500 to 20,000 psi = 120% FS
Burst Pressure:
15 to 2000 psi = 800% FS
3000 to 5000 psi = 300% FS
7500 to 20,000 psi = 150% FS
Gages: Thin-film polysilicone
Diaphragm: 17-4 PH stainless steel
Case: 300 Series stainless steel
Pressure Connection:
15 to 10,000 psi = 1/4; NPT
>10,000 psi = female Aminco fitting (9/16-18 UNF)
Electrical Connection: 0.9 m (36′) braided-shield PVC cable or connector
Mating Connector: PT06F8-4S (not included)
Weight: 128 g (4.5 oz) without cable
Response Time: 5 ms
Construction: Sealed units, except PX603 and PX605 ≤500 psi is vented to room
Enquiry for Dwyer Omega – PX603-PX613-PX605-PX615 General Purpose Pressure Transducers with Adjustable Zero & Span
Please complete the short form below:
Product Shortform Catalogue
View our product catalogue.
View Catalogue
Daniel Product Overview
View the Daniel Product overview for pressure, level and temperature measurement including accessories.
View Here
Siemens Catalogue
View the Siemens Products for Process Instrumentation catalogue.
View Here