SPECIFICATIONS
Excitation: 10 to 36 Vdc unregulated
Output: PX603/PX613 Series: 1 to 5 Vdc (3 wire)
PX605/PX615 Series: 4 to 20 mA (2 wire)
Supply Current: <3.0 mA
Insulation Resistance: 100 MΩ @ 50 V
Accuracy: ± 0.4% BFSL (Includes non-linearity, hysteresis and non-repeatability errors)
± 1.0% Terminal Point Method Includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors
Hysteresis: ± 0.2% FS
Repeatability: ± 0.07% FS
Stability: ± 1.0%/year
Durability: 100 million cycles
Operating Temperature: -28 to 82°C (-20 to 180°F)
Compensated Temperature: -28 to 71°C (-20 to 160°F)
Thermal Zero Effect: ± 0.04% FS/°F
Thermal Span Effect: ± 0.04% FS/°F
Proof Pressure:
15 to 2000 psi = 200% FS
3000 to 5000 psi = 150% FS
7500 to 20,000 psi = 120% FS
Burst Pressure:
15 to 2000 psi = 800% FS
3000 to 5000 psi = 300% FS
7500 to 20,000 psi = 150% FS
Gages: Thin-film polysilicone
Diaphragm: 17-4 PH stainless steel
Case: 300 Series stainless steel
Pressure Connection:
15 to 10,000 psi = 1/4; NPT
>10,000 psi = female Aminco fitting (9/16-18 UNF)
Electrical Connection: 0.9 m (36′) braided-shield PVC cable or connector
Mating Connector: PT06F8-4S (not included)
Weight: 128 g (4.5 oz) without cable
Response Time: 5 ms
Construction: Sealed units, except PX603 and PX605 ≤500 psi is vented to room

  • Excellent Long Term Stability
  • All Stainless Steel Construction
  • NEMA 4 Cable or Connector Models
  • 0.4% Accuracy