EMCO Meter Run with Transmitter Flanges for Compact Mounting
Product Code: CompaQ
Manufacturer: EMCO
EMCO Meter Run type CompaQ is used as primary element in flow measurement of liquid, gas and steam according to the differential pressure principle.
The differential pressure transmitter and 3 way manifold valve is mounted directly on the CompaQ ensuring an faster and more safe installation on site.
-
EMCO meter runs with carrier rings fit between two sections of straight cylindrical pipe.
-
The straight pipe sections must have a constant cross-sectional area and no obstructions.
-
Minimum straight pipe lengths required depend on beta (β) and the presence of obstructions like bends or reducers.
-
A table indicates how many times the inner pipe diameter (D) is needed for “zero additional uncertainty.”
-
Values in brackets denote “+/-0.5% additional uncertainty” for specified pipe lengths.
-
If the straight pipe length is shorter than bracketed values, additional uncertainty details are unavailable.