Search our website
Dwyer Omega – Series AVLV Air Velocity Transmitter ± 1% Accuracy, Configurable Outputs, BACnet/Modbus
Click to enlarge

Dwyer Omega – Series AVLV Air Velocity Transmitter ± 1% Accuracy, Configurable Outputs, BACnet/Modbus

Dwyer Omega – Series AVLV Air Velocity Transmitter ± 1% Accuracy, Configurable Outputs, BACnet/Modbus

Product Code: Series AVLV

Manufacturer: Dwyer Omega


The Series AVLV Air Velocity Transmitter quickly and accurately measures air velocity or volumetric flow in imperial or metric units. Simultaneous current and voltage outputs on all models provide universal inputs to monitoring equipment while the output range, units, and 0-5/10 VDC, 4-20 mA output can be configured via local DIP switches. The optional integral display, or the portable remote tool, provide a convenient way to local monitor process values and configure the unit. Models are available in 1% and 2% accuracy models and low velocity ranges to suit a variety of needs, and the optional BACnet MS/TP or Modbus® RTU/ASCII communication protocol allows units to be daisy-chained while providing access to all of the velocity and flow data, as well as additional information such as air temperature. The lower ranges in these high accuracy units allow for applications in quality intensive environments, such as the pharmaceutical industry.

Air Velocity, Max

400 FPM

Air Velocity, Min

20 FPM

Air Velocity Note

100, 200, 300, 400 FPM (0.5, 1, 1.5, 2 m/s); Field selectable

Applications

Clean Rooms, Pharmaceutical

Baud Rate

N/A

Compliance

BTL, CE

Device Load

1/8 Unit

Enclosure Ratings

IP66, NEMA Type 4X

Load Resistance

Current output: 0 to 1100 Ω max; Voltage Output: 1 kΩ min

Materials, Wetted

Consult Factory

Media Compatibility

Argon, Carbon dioxide, Clean Dry Air, Helium, Nitrogen, Non-Corrosive Dry Gases

Mounting Orientation

Sensor Tip Parallel to Flow

Operating Temperature, Max

122 °F

Operating Temperature, Min

32 °F

Output Detail

4 to 20 mA; 0 to 5 Vdc, 0 to 10 Vdc

Output Signal

Current, Voltage

Power Consumption

60 mA + Output Current

Relative Humidity

5 to 95% RH Non-Condensing

Response Time

4 s

Response Time Note

4 s, typical; 1 s at constant temperature

Supply Power Type

AC/DC

Supply Voltage

19 to 30 Vdc/Vac

Weight

6 oz

Wire Gauge

26 to 16 AWG

Zero Setting Adjustable Range

Digital Push Buttons

  • Sensing elements have been coated with an engineered conformal coating to ensure durability and longevity
  • Field selectable ranges can be quickly configured without power to the unit
Datasheet Download
Instruction Manual Download

The new way to pay from Process Instrument Solutions.

Similar Products