The HX94 relative humidity/ temperature transmitter provides a reliable and low cost method for duct mount monitoring applications. Solid state sensors provide excellent sensitivity, fast response, and stability. Simple hookup and linearised output permit interfacing with most display and control devices. The NEMA 4 stainless steel enclosure and cable entry connection provides weather tight protection. The digital temperature and relative humidity sensor is protected by a stainless steel cap that is easily removed for cleaning.
Accuracy
±0.6 °C
Cable Length
305 mm
Enclosure Ratings
NEMA Type 4
Flange Note
Removable, variable 25.4 to 227 mm (1 to 9″) depth; 70 mm (2.75″) dia., duct hole 21 mm (0.812″) dia. 4 mtg holes. 4 mm (0.156″) dia. (for #6 sheet metal screws) on 51 mm (2.00″) dia. circle; wall mounting bracket included
Flange Size
227 mm
Measurement Type
Temperature, Humidity
Probe Diameter
19 mm
Probe Length
254 mm
Relative Humidity
3 to 95%
Relative Humidity Accuracy
± 2% RH
Repeatability
± 0.3°C
Supply Power Type
DC
Temperature Measurement, Max
85 °C
Temperature Measurement, Min
-20 °C
Time Constant
(for 60% response) Less than 2 sec in moving air (1m/sec) less than 10 sec in still air
Time Constant, Relative Humidity
(for 90% response at 25°C; in moving air, 1m/sec.) Less than 20 seconds, 10 to 90% RH Less than 30 seconds, 90 to 10% RH
The HX94 relative humidity/ temperature transmitter provides a reliable and low cost method for duct mount monitoring applications. Solid state sensors provide excellent sensitivity, fast response, and stability. Simple hookup and linearised output permit interfacing with most display and control devices. The NEMA 4 stainless steel enclosure and cable entry connection provides weather tight protection. The digital temperature and relative humidity sensor is protected by a stainless steel cap that is easily removed for cleaning.
Accuracy
±0.6 °C
Cable Length
305 mm
Enclosure Ratings
NEMA Type 4
Flange Note
Removable, variable 25.4 to 227 mm (1 to 9″) depth; 70 mm (2.75″) dia., duct hole 21 mm (0.812″) dia. 4 mtg holes. 4 mm (0.156″) dia. (for #6 sheet metal screws) on 51 mm (2.00″) dia. circle; wall mounting bracket included
Flange Size
227 mm
Measurement Type
Temperature, Humidity
Probe Diameter
19 mm
Probe Length
254 mm
Relative Humidity
3 to 95%
Relative Humidity Accuracy
± 2% RH
Repeatability
± 0.3°C
Supply Power Type
DC
Temperature Measurement, Max
85 °C
Temperature Measurement, Min
-20 °C
Time Constant
(for 60% response) Less than 2 sec in moving air (1m/sec) less than 10 sec in still air
Time Constant, Relative Humidity
(for 90% response at 25°C; in moving air, 1m/sec.) Less than 20 seconds, 10 to 90% RH Less than 30 seconds, 90 to 10% RH